Other tests were performed to measure the bucket coil resistance before and after a test firing to observe heating effects at different currents. These tests are summarized in Tables 3.4 and 3.5 for the two different buckets. Table 3.3 Ohmic bucket resistance as a function of time after removal from liquid nitrogen. time (sec) = 0.514 bucket resistance () = 0.63 bucket resistance () q= 0.65 bucket resistance () 0 96.0 62.4 92.8 5 97.3 63.5 93.7 10 99.9 66.6 98.9 15 104.9 71.8 107.3 20 111.2 77.7 117.8 25 119.0 83.8 128.2 30 126.5 90.6 138.9 40 143.3 103.1 161.0 50 159.4 116.5 183.5 60 176.1 128.6 205 80 210.2 151.5 242 100 237 173.2 279 120 264 195 309 150 302 221 351 180 335 246 387 210 367 269 420 240 395 289 450 270 421 306 476 300 445 323 500 00 905 577 849